膜接触器吸收二氧化碳过程中的膜润湿研究
作者:崔丽云,王宇,李云鹏,丁忠伟,刘丽英
单位: 北京化工大学 化学工程学院,北京 100029
关键词: 聚偏氟乙烯;二乙醇胺;膜接触器;膜润湿
出版年,卷(期):页码: 2014,34(4):33-39

摘要:
自制疏水性聚偏氟乙烯(PVDF)中空纤维膜膜组件,采用二乙醇胺(DEA)溶液为吸收液进行二氧化碳吸收实验,研究了在膜接触器中的微孔膜润湿随操作时间的变化,以及吸收液浓度和温度对膜润湿的影响。实验结果表明:随着吸收过程的进行,膜润湿百分率逐渐增加;膜润湿随着DEA溶液浓度的增大而下降;升高温度促进了微孔膜的润湿。利用微孔膜渗入机理,Fick定律和膜孔径对数分布函数,我们提出了膜吸收过程中膜润湿百分率随时间变化的理论方程,并且对实验数据进行了拟合,得到了较好的拟合效果;同时理论上分析了膜润湿对总传质系数的影响。
 The hollow fiber membrane of hydrophobic polyvinylidene fluoride (PVDF) was used to make membrane module to the CO2 absorption, and the diethanol amine (DEA) aqueous solution was applied as absorbent. In this paper, we studied the membrane wetting process in membrane contactor, and the influence factors of concentration of DEA and solution temperature. The experimental results indicate that, the membrane wetness increased with the absorption process; increasing the solution concentration of DEA hindered the membrane wetting; however, rising the solution temperature could accelerate the membrane wetting. According to the kinetics of micropore imbibitions, Fick-law and membrane pores distribution, we put forward a theory equation between the membrane wetness and wetting time, and successfully fitted the membrane wetting results in gas absorptions. Simultaneously, we analyzed the influence of membrane wetting on the mass transfer coefficient in theory.
崔丽云(1987-),女,山东人,博士生,主要从事膜分离方向研究;

参考文献:
[1] Li, Jing-Liang, Bing-Hung Chen. Review of CO2 absorption using chemical solvents in hollow fiber membrane contactors [J]. Sep Purif Technol, 2005,41: 109-122.
[2] P. Keshavarz, J. Fathikalajahi, S. Ayatollahi. Analysis of CO2 separation and simulation of a partially wetted hollow fiber membrane contactor [J]. J Hazard Mater, 2008, 152: 1237-1247.
[3] JianGang Lu, YouFei Zheng, MinDong Cheng. Wetting mechanism transfer process of hydrophobic membrane gas absorbtion [J]. J Membr Sci, 2008, 308: 180-190.
[4] R. Wang, H.Y. Zhang, P.H.M. Feron, et al. Influence of membrane wetting on CO2 capture in microporous hollow fiber membrane contactors [J]. Sep Purif Technol, 2005, 46: 33-40.
[5] S. Khaisri, D. deMontigny, P. Tontiwachwuthikul, A mathematical model for gas absorption membrane contactors that studies the effect of partially wetted membranes, J. Membr. Sci. 347 (2010) 228-239.
[6] H.Y Zhang, R Wang, D.T. Liang, J.H Tay, Theoretical and experimental studies of membrane wetting in the membrane gas-liquid contacting process for CO2 absorption, J. Membr. Sci. 308 (2008) 162-170.
[7] K.S. Lee, N. Ivanova, V.M. Starov, et al. Kinetics of wetting and spreading by aqueous surfactant solutions [J]. Adv Colloid Interface Sci, 2008, 144: 54-65
 

服务与反馈:
文章下载】【加入收藏

《膜科学与技术》编辑部 地址:北京市朝阳区北三环东路19号蓝星大厦 邮政编码:100029 电话:010-64426130/64433466 传真:010-80485372邮箱:mkxyjs@163.com